翻訳と辞書
Words near each other
・ Timeless Passages
・ Time-Life Building
・ Time-Life Building (Chicago)
・ Time-Life Building (disambiguation)
・ Time-Life Television
・ Time-Line
・ Time-Megeve-Mont-Blanc
・ Time-multiplexed optical shutter
・ Time-of-flight camera
・ Time-of-flight diffraction ultrasonics
・ Time-of-flight mass spectrometry
・ Time-of-flight ultrasonic determination of 3D elastic constants
・ Time-out (parenting)
・ Time-out (sport)
・ Time-Place learning
Time-resolved fluorescence energy transfer
・ Time-resolved mass spectrometry
・ Time-resolved photon emission
・ Time-resolved spectroscopy
・ Time-saving bias
・ Time-scale calculus
・ Time-Sensitive Networking
・ Time-series segmentation
・ Time-sharing
・ Time-sharing system evolution
・ Time-slot interchange
・ Time-to-digital converter
・ Time-tracking software
・ Time-trade-off
・ Time-triggered architecture


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Time-resolved fluorescence energy transfer : ウィキペディア英語版
Time-resolved fluorescence energy transfer
Time-Resolved Fluorescence Energy Transfer (TR-FRET) is the practical combination of time-resolved fluorometry (TRF) combined with fluorescence resonance energy transfer (FRET) that offers a powerful tool for drug discovery researchers. TR-FRET combines the low background aspect of TRF with the homogeneous assay format of FRET. The resulting assay provides an increase in flexibility, reliability and sensitivity in addition to higher throughput and fewer false positive/false negative results. FRET involves two fluorophores, a donor and an acceptor. Excitation of the donor by an energy source (e.g. flash lamp or laser) produces an energy transfer to the acceptor if the two are within a given proximity to each other. The acceptor in turn emits light at its characteristic wavelength.
The FRET aspect of the technology is driven by several factors, including spectral overlap and the proximity of the fluorophores involved, wherein energy transfer occurs only when the distance between the donor and the acceptor is small enough. In practice, FRET systems are characterized by the Förster's radius (R0): the distance between the fluorophores at which FRET efficiency is 50%. For many FRET parings, R0 lies between 20 and 90 Å, depending on the acceptor used and the spatial arrangements of the fluorophores within the assay.〔()〕 Through measurement of this energy transfer, interactions between biomolecules can be assessed by coupling each partner with a fluorescent label and detecting the level of energy transfer. Acceptor emission as a measure of energy transfer can be detected without needing to separate bound from unbound assay components (e.g. a filtration or wash step) resulting in reduced assay time and cost.
== Advantages ==

Homogeneous, mix-and-read TR-FRET assays offer advantages over other biomolecular screening assays, such as fluorescence polarization (FP) or TRF assays. In FP assays, background fluorescence due to library compounds is normally depolarized and background signal due to scattered light (e.g. precipitated compounds) is normally polarized. Depending on the assay configuration, either case can lead to a false positive or false negative result. However, because the donor species used in a TR-FRET assay has a fluorescent lifetime that is many orders of magnitude longer than background fluorescence or scattered light, emission signal resulting from energy transfer can be measured after any interfering signal has completely decayed. TR-FRET assays can also be formatted to use limiting receptor and excess tracer concentrations (unlike FP assays), which can provide further cost savings. In the case of TRF assays, a wash step is required to remove unbound fluorescent reagents prior to measuring the activity signal of the assay. This increases reagent use, time to complete the assay, and limits the ability to miniaturize the system (e.g. converting from a 384-well microtiter plate to a 1536-well plate). TR-FRET assays take advantage of the required proximity of the donor and acceptor species for generation of signal.
Additionally, this method is preferred by some researchers as it does not rely on radioactive materials to generate the signal to be detected. This avoids both the hazards of using the materials and the cost and logistics of storage, use, and disposal.